      Visqueen NF-Detailing Strip, 300mm x 10m

      Visqueen NF-Detailing Strip is a single sided strip, consisting of a white coloured polymer carrier film coated with a grey coloured cold weather butyl adhesive compound protected with a release film. It is available in roll format, 300mm x 10m.

      Global

      Meta title
      NF Detailing Strip | Visqueen NF Detailing Tape
      Meta Description
      Non-foil detailing strip for junctions and penetrations. Available in 300mm width.
      Berry Global EntityEM
      Products
      • Building Materials
        • Infrastructure
          • Gas Protection
        Brands
        • EMO
          • Visqueen®
          Brand URL
          www.visqueen.com
          Markets
          • Building & Construction
            • Infrastructures
              • Commercial Construction
                • Renovation & Restoration
                  • Residential Construction
                  Factory Locations
                  • Visqueen HQ
                  Country Serviced / Available In
                  • Europe
                    Features / Benefits

                    BDA Agrement Certified detailing material - third party accreditation
                    Flexible - can be cut and shaped to various applications
                    Multi-use - suitable for complicated junctions, stanchions, patchwork and terminations
                    Gas resistant non foil self adhesive detailing membrane

                    End Use / Recommended Applications
                    Visqueen NF-Detailing Strip is used for sealing junctions and complicated detailing in Visqueen gas protection systems, waterproofing systems, and damp proofing systems. It can be used on concrete, blockwork, brickwork, particle boards, steel work, steel stanchions and wooden substrates for both vertical and horizontal application.

                    + Visqueen

                    Publish Date
                    17/02/2026 00:00:00
                    Product Keywords
                    detailing strip non foil BDA agrement certificate
                    Approvals and Standard
                    BDA Agrement Certified detailing material - third party accreditation Complies with the methane gas transmission rate, mass per unit area and thickness requirements of BS 8485:2015 + A1:2019 - industry standard for methane and carbon dioxide protection Suitable for all Characteristic Gas Situation (CS) ground gas regimes Conforms to the specification requirements of NHBC Amber 1 and Amber 2 applications Conforms to the specification requirements of BR 211:2023 Visqueen certified with Quality Management System ISO 9001:2015 Visqueen certified with Occupational Health and Safety System ISO 45001:2018 Visqueen certified with Environmental Management System ISO 14001:2015
                    Usage
                    Visqueen NF-Detailing Strip is used for sealing junctions and complicated detailing in Visqueen gas protection systems, waterproofing systems, and damp proofing systems. It can be used on concrete, blockwork, brickwork, particle boards, steel work, steel stanchions and wooden substrates for both vertical and horizontal application.
                    Storage and Handling
                    Store in dry and clean environment in its current packaging. The product should not be exposed to long periods of ultraviolet light. Care should be taken when handling the product in line with current manual handling regulations. For ease of installation, during hot weather conditions (>25°C), it is recommended to store the product in a cool location prior to use.
                    Preparation
                    Surfaces must be smooth and free from sharp protrusions, ensure the surface and working area is not water logged and is frost free. When applying to blockwork or brickwork the joints must be flush pointed. Prior to bonding, substrates such as masonry, concrete and steel should be primed using Visqueen HP Tanking Primer and allowed to dry thoroughly. Visqueen HP Tanking Primer must not be used on Insulation or ICF systems. Visqueen NF-Detailing Strip can be cut with a sharp retractable safety knife. Hand rollers are required during application. Typical hand rollers include 40mm silicone pressure roller and 6mm brass penny pressure roller.
                    Installation
                    Position and peel back the Visqueen NF-Detailing Strip release film and apply the pressure sensitive, self adhesive grey face to the prepared substrate. Apply pressure by rollering to ensure a full bond is achieved. All lap joints should be a minimum of 150mm and must be pressed and rolled to ensure damp, gas or waterproofing continuity. When used for sealing membranes punctures, Visqueen NF-Detailing Strip should be lapped at least 150mm beyond the extents of the puncture.
                    Usable temperature range
                    It is recommended that Visqueen NF-Detailing Strip should be installed above -5°C. Prior to installation, ensure that frost or ice is not present on the substrate. For ease of installation, during hot weather conditions (>25°C), it is recommended to store the product in a cool location prior to use.
                    Additional information
                    The information in this datasheet was correct at the time of publication. It is the user’s responsibility to obtain the latest version of the datasheet as it is updated on a regular basis. The information contained in the latest datasheet supersedes all previously published editions.
                    Health and safety information
                    Refer to the Visqueen-NF Detailing Strip safety datasheet (SDS)
                    • steve darcy
                    • Product -> Berry Global Product
                    • English
                    • Created 21 Mar 2025
                    • Modified 04 Jun 2026
                    • Hits 126