Mecmesin's Plastic Phial Cap Removal Test

Specification

Point Plastics approached Mecmesin with a specification to pull-off the cap of a pharmaceutical phial. The test equipment needed to be simple to use and able to perform repeatable tests.

Solution

For ease of fixturing and low cost, Mecmesin suggested to the customer to turn his sample upside-down and push-off the cap. In this case, the force to push was the same as the force to pull. The customer agreed and a simple holding fixture was designed.

The plastic phial was inserted from below the fixture until it's full depth and secured by a locking screw. The long extension rod of the AFG passed through a clearance hole until it reached the cap and pushed it off.

The maximum compression force was displayed on the AFG display and noted by the operator. The alarm band of the AFG was set to warn the operator if the push-off force was inside/outside the tolerance limits.

System

  • 1000 N Motorised Test Stand
  • Advanced Force Gauge 50N
  • Plastic Phial Holding Fixture

See also

Tensile testing wire joining systems

Our customer's wire joiners and tensioners are used extensively in the Building Services, Agriculture, Civil Engineering, Viticulture and Seismic Construction sectors and feature award-winning solutions for clamping, seismic bracing, suspension and hanging systems. As part of the continuous improvement ethic, the Quality and Design Department wanted to review their in-house methods and re-evaluate the test procedures for measuring break loads in their cable components.