+ Visqueen | |
| Publish Date | 19/02/2026 00:00:00 |
|---|---|
| Product Keywords detailing, detailing, detailing, self adhesive, detail, detailing, junction, junctions, gas, damp | |
| Branch ID | 1089 |
| Approvals and Standard Complies with the methane gas transmission rate, mass per unit area and thickness requirements of BS 8485:2015 + A1:2019 - industry standard for methane and carbon dioxide protection
Suitable for all Characteristic Gas Situation (CS) ground gas regimes
Conforms to the specification requirements of NHBC Amber 1 and Amber 2 applications
Conforms to the specification requirements of BR 211:2023
Visqueen certified with Quality Management System ISO 9001:2015
Visqueen certified with Occupational Health and Safety System ISO 45001:2018
Visqueen certified with Environmental Management System ISO 14001:2015 | |
| Usage VisqueenPro Detailing Strip is used for sealing junctions and complicated detailing in Visqueen gas protection systems, waterproofing systems, and damp proofing systems. It can be used on concrete, blockwork, brickwork, particle boards, steel work, steel stanchions and wooden substrates for both vertical and horizontal application. | |
| Storage and Handling Store in a dry and clean environment in its current packaging. The product must be stored upright.
VisqueenPro Detailing Strip can be cut with a sharp retractable safety knife.
Care should be taken when handling the product in line with current manual handling regulations. | |
| Preparation Surfaces must be smooth and free from sharp protrusions, ensure the surface and working area is not water logged and is frost free. When applying to blockwork or brickwork the joints must be flush pointed. Prior to bonding, substrates such as masonry, concrete and steel should be primed using Visqueen HP Tanking Primer and allowed to dry thoroughly. Visqueen HP Tanking Primer must not be used on Insulation or ICF systems. | |
| Installation Position and peal back the VisqueenPro Detailing Strip release film and apply the pressure sensitive, self adhesive face to the prepared substrate. Apply pressure by rollering to ensure a full bond is achieved. All lap joints should be a minimum of 150mm and must be pressed and rolled to ensure damp, gas or waterproofing continuity.
When used for sealing membranes punctures, VisqueenPro Detailing Strip should be lapped at least 150mm beyond the extents of the puncture. | |
| Usable temperature range It is recommended that VisqueenPro Detailing Strip should be installed above -5°C. Prior to installation, ensure that frost or ice is not present on the substrate. | |
| Additional information The information in this datasheet was correct at the time of publication. It is the user’s responsibility to obtain the latest version of the datasheet as it is updated on a regular basis. The information contained in the latest datasheet supersedes all previously published editions.
VisqueenPro Detailing Strip data table | |
| Health and safety information Refer to the VisqueenPro Detailing Strip safety datasheet (SDS) | |